Results 1 - 20 de 49
Filter
1.
Article in English | MEDLINE | ID: mdl-38712751

ABSTRACT

OBJECTIVE: This randomised clinical trial assessed the impact on symptoms, tear film dynamics and ocular surface integrity of daily disposable silicone-hydrogel contact lenses (CLs) over a month, paying special attention to lid wiper epitheliopathy (LWE) and its implications for CL discomfort. METHODS: Neophyte CL wearers (n = 44, 21.09 ± 5.00 years old) were randomly assigned to either the experimental (n = 24) or control group (n = 20). Participants assigned to the experimental group were required to wear daily disposable CLs for 1 month for at least 8 h/day and 6 days/week. All participants were healthy subjects (no history of ocular surgery or active ocular disease) with spherical refractive errors between -8.00 and +5.00 D and cylindrical power <0.75 D. At the baseline and 1-month sessions, the Dry Eye Questionnaire 5 (DEQ-5) was completed, together with the measurement of tear film osmolarity with the TearLab osmometer, tear meniscus height (TMH) and lipid layer pattern (LLP) using a slit-lamp with Tearscope Plus attached, fluorescein break-up time (FBUT), maximum blink interval (MBI), corneal staining with fluorescein under cobalt blue light and LWE with lissamine green under slit lamp and halogen white light. RESULTS: At the baseline session, LWE showed a negative correlation with DEQ-5 (r = -0.37, p = 0.02). Significant differences in FBUT and LWE (p = 0.04) and a positive correlation between LWE and DEQ-5 (r = 0.49, p = 0.007) were observed at 1 month. Intrasession analysis at 1 month showed significant differences between the experimental and control groups in DEQ-5, FBUT and LWE (all p ≤ 0.02). Intersession analysis in the experimental group showed variations in DEQ-5, FBUT and LWE (all p ≤ 0.02) but no significant variation in the control group (all p ≥ 0.11). CONCLUSION: The presence of LWE was significantly correlated with higher symptom values in the DEQ-5. Also, participants in the experimental group presented higher values of LWE after 1 month of CL wear, in comparison with the control group.

2.
J Clin Med ; 13(3)2024 Jan 23.
Article in English | MEDLINE | ID: mdl-38337353

ABSTRACT

(1) Background: Dry eye disease (DED) is a chronic ocular surface condition that requires precise diagnostic tools. The present study aimed to investigate the diagnostic potential of the absolute inter-eye difference (|OD-OS|) in tear meniscus height (TMH) for the detection of the presence of aqueous deficient dry eye (ADDE). (2) Methods: A sample of 260 participants with dry eye complaints underwent ocular surface examinations thorough diagnostic assessments based on the Tear Film and Ocular Surface Society guidelines (TFOS DEWS II). Participants were subsequently categorized as No ADDE and ADDE based on TMH. Statistical analyses to determine the optimal TMH|OD-OS| cut-off value in a randomly selected study group (200 participants) were performed, while a separate validation analysis of the cut-off value obtained in a random cross-validation group (60 participants) was also performed. (3) Results: The significant diagnostic capability of TMH|OD-OS| (area under the curve = 0.719 ± 0.036, p < 0.001) was found. The identified cut-off value of 0.033 mm demonstrated reliable specificity (77.6%) and moderate sensitivity (59.1%). Cross-validation confirmed the cut-off value's association with the TFOS DEWS II diagnostic criterion (Cramer's V = 0.354, p = 0.006). (4) Conclusions: The present study provides evidence for the diagnostic potential of TMH|OD-OS| in identifying ADDE. The identified cut-off value enhances the specificity and offers moderate sensitivity, providing an objective tool for clinical decision making.

3.
Clin Exp Optom ; : 1-6, 2024 Jan 09.
Article in English | MEDLINE | ID: mdl-38194485

ABSTRACT

CLINICAL RELEVANCE: Due to the long-time that wind musicians spend playing their instruments, it is important to investigate if intraocular pressure could be affected by this activity. BACKGROUND: To assess the intraocular pressure fluctuations and fluctuations affecting factors in professional wind musicians while playing different tones. METHODS: Thirty professional wind musicians (23.0 ± 3.20 years) were recruited from the Professional Music College of A Coruña. A questionnaire about environmental/demographic factors was given to participants. Intraocular pressure was measured four times by ICare IC100 tonometer: before, during low and high-pitched tones, and immediately after stopping playing the wind instrument. RESULTS: Pairwise comparison revealed statistical differences between measurement points (Sidak, all p ≤ 0.019), except between before playing and while playing low-pitched tones (Sidak, p = 1.000). Intraocular pressure increases during high pitch playing and decreases after stopping playing. No significant differences in intraocular pressure fluctuation were reported between physically active (>2 days/week) and non-physically active participants (Unpaired t-test, p = 0.680). All intraocular pressure values were positively correlated (Pearson's correlation, all r ≥ 0.505, p ≤ 0.004). Intraocular pressure fluctuations were negatively correlated with musical playing years (Pearson's correlation, r = - 0.396, p = 0.030). There were no significant correlations among intraocular pressure fluctuation and gender, age, weight, height, or daily time playing (Pearson's correlation, all p ≥ 0.058). CONCLUSION: Professional wind musicians suffer intraocular pressure peaks while playing high-pitched tones; therefore, ocular fundus evaluation and visual campimetry should be performed as routine tests in the visual exam of this population.

4.
Arq. bras. oftalmol ; 87(3): e2022, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1520214

ABSTRACT

ABSTRACT Purpose: The possible variability in diagnostic test results is a statistical feature of dry eye disease patients. The clinician should consider tear film variations over time since the timing of tear film measurements is important for proper diagnosis. The purpose of the present study was to analyze the inter-week variation of osmolarity measurement in healthy and dry eye disease participants. Methods: Based on the Dry Eye Workshop II (DEWS-II) diagnostic methodology report criteria, a battery of tests (Ocular Surface Disease Index [OSDI] questionnaire, breakup time, and corneal staining) was administered to rule out the presence of dry eye disease. A total of 40 qualified volunteers were recruited into two groups: with only 20 healthy and 20 dry eye disease participants. The inter-week variation of osmolarity in the two groups was measured using a TearLab osmometer in two sessions one-week apart. The differences between the results were calculated. Results: There were no significant differences in osmolarity between the two sessions for either the healthy (paired t-test; p=0.085) or dry eye disease (paired t-test; p=0.093) participants. Moreover, there was no significant correlation between the means and differences in either session on healthy (Pearson correlation: r=0.020; p=0.935) or dry eye disease (Pearson correlation: r=-0.022; p=0.928) participants. In session 1, there was a significant difference in osmolarity values between groups (unpaired t-test; p=0.001), but no difference was found in session 2 (unpaired t-test; p=0.292). Conclusions: The present study discovered no inter-week variation in the tear film osmolarity of healthy and dry eye disease participants classified based on the DEWS-II criteria.


RESUMO Objetivo: A possível variabilidade nos resultados de testes diagnósticos é uma característica estatística dos pacientes com síndrome do olho seco. O médico deve considerar as variações do filme lacrimal ao longo do tempo, pois o momento em que o filme lacrimal é medido pode ser crítico para o diagnóstico adequado. O objetivo deste estudo foi analisar a variação semanal da osmolaridade do filme lacrimal em participantes saudáveis e em outros com síndrome do olho seco. Métodos: Com base nos critérios da metodologia de diagnóstico do relatório da Dry Eye Workshop II (DEWSII), foi aplicada uma bateria de testes (questionário do índice de doença da superfície ocular [OSDI], tempo de ruptura do filme lacrimal e coloração da córnea) para descartar a presença de síndrome do olho seco. Um total de 40 voluntários qualificados foi recrutado e distribuído em dois grupos de 20 participantes saudáveis e 20 participantes com síndrome do olho seco. A variação da osmolaridade entre semanas foi medida com um osmômetro TearLab em duas sessões com uma semana de intervalo nos dois grupos. As diferenças entre os resultados foram então calculadas. Resultados: Não foram encontradas diferenças significativas na osmolaridade entre as medidas obtidas nas duas sessões, nem no grupo de participantes saudáveis (teste de t pareado; p=0,085), nem no de participantes com síndrome do olho seco (teste de t pareado; p=0,093). Não foi detectada nenhuma correlação significativa entre as médias e diferenças entre as duas sessões entre participantes saudáveis (correlação de Pearson: r=0,020, p=0,935) e aqueles com síndrome do olho seco (correlação Pearson: r=-0,022, p=0,928). Foi encontrada uma diferença significativa nos valores de osmolaridade entre os dois grupos na primeira sessão (teste de t não pareado; p=0,001), mas nenhuma diferença foi encontrada na segunda sessão (teste de t não pareado; p=0,292). Conclusões: O presente estudo não encontrou variação entre semanas consecutivas na osmolaridade do filme lacrimal em participantes saudáveis e com síndrome do olho seco, classificados com base nos critérios do DEWSII.

5.
Ocul Immunol Inflamm ; : 1-8, 2023 Dec 05.
Article in English | MEDLINE | ID: mdl-38051590

ABSTRACT

PURPOSE: Inter-eye variability is a recognized characteristic of Dry Eye Disease (DED) and has been proposed as a diagnostic indicator in clinical practice. This study aimed to assess the diagnostic potential of the absolute difference between eyes in three key diagnostic tests recommended by the Tear Film and Ocular Surface Society Dry Eye Workshop II (TFOS DEWS II) Diagnostic Methodology report: tear film osmolarity, Fluorescein Break-Up Time (FBUT), and ocular surface staining. METHODS: A total of 180 participants were included in a cross-sectional study. Before a dry eye examination, participants completed an online self-administered OSDI questionnaire. The TFOS DEWS II diagnostic criteria for DED assessment were used: along with OSDI, osmolarity, FBUT and ocular surface staining were measured in all participants in both eyes following standardized methodology. Based on signs and symptoms, participants were diagnosed as having No DED or DED. After diagnosis, the parameters were computed as the right and left eyes' absolute inter-eye difference (|OD-OS|). RESULTS: Receiver Operating Characteristics analyses for computed parameters were used based on the previous diagnosis. ROC analyses showed that Osmolarity|OD-OS| have a diagnostic capability to differentiate between No DED and DED participants with a cut-off value of 9.5 mOsm/L (AUC = 0.745 ± 0.052, p < 0.003), whereas FBUT|OD-OS| and Corneal Stainning|OD-OS| have not (AUC, both p ≥ 0.160). CONCLUSION: The present study found that the Osmolarity|OD-OS| parameter could be used as a diagnostic indicator for DED assessment, while the FBUT|OD-OS| and the Corneal Staining|OD-OS| parameters do not have this capability.

6.
Cureus ; 15(11): e48826, 2023 Nov.
Article in English | MEDLINE | ID: mdl-38106705

ABSTRACT

Purpose To compare intraocular pressure (IOP) values at different time points, both in the total sample and according to iridocorneal angle aperture, to assess whether IOP fluctuations were constant throughout the day, and to examine correlations with other factors. Methods Over a single day, the IOP of 34 volunteers was measured at three-hour intervals from 9:00 a.m. to 6:00 p.m. To avoid any IOP value being affected by other measurements, anamnesis, slit-lamp evaluation (with iridocorneal angle measurement), and refractive status were performed after the final measurement. The differences between IOP values at different time points and IOP fluctuation at three-hour intervals were compared by ANOVA and Friedman test, respectively, both for the total group and according to iridocorneal angle aperture. For relationships, Pearson's correlation was performed for parametric variables and Spearman's correlation for nonparametric variables. Results Significant differences were observed in IOP between time points for the total sample (p < 0.001), but not for a narrow-angle group (p = 0.058). No significant differences were found in IOP fluctuations at three-hour intervals either in the total sample or according to angle aperture (all p ≥ 0.332). There was a positive correlation of IOP at different time points (all r ≥ 0.646, all p < 0.001) but no relationship with spherical equivalent, age, or sleep duration (all p ≥ 0.057). IOP at 12:00 p.m. was correlated with a 12:00 p.m. to 3:00 p.m. fluctuation (r = 0.428, p = 0.012); and IOP fluctuation between 9:00 a.m. and 12:00 p.m. was correlated with age (r = 0.485, p = 0.004). Conclusion As IOP decreases from morning until at least 6:00 p.m., measuring these two values during clinical evaluation is essential for the effective monitoring and prevention of IOP-related diseases.

7.
Pharmaceutics ; 15(11)2023 Nov 05.
Article in English | MEDLINE | ID: mdl-38004568

ABSTRACT

BACKGROUND: Cystinosis is a rare genetic disorder characterized by the accumulation of cystine crystals in several tissues and organs causing, among others, severe eye symptoms. The high instability of cysteamine eye drops makes it difficult to develop formulations with an acceptable shelf life to be prepared in hospital pharmacy departments. Previously, a new compounded formulation of cysteamine eye drops in hyaluronic acid (HA) packaged in innovative single-dose systems was developed. METHODS: Long-term stability at -20 °C of this formulation was studied considering the content of cysteamine, pH, osmolality, viscosity, and microbiological analysis. The oxygen permeability of single-dose containers was also studied and an ocular biopermanence study was conducted in healthy volunteers measuring lacrimal stability and volume parameters. RESULTS: Data confirm that cysteamine concentration remained above 90% for 120 days, all parameters remaining within the accepted range for ophthalmic formulations. The permeability of the containers was reduced over time, while ocular biopermanence was maintained despite the freezing process and storage time. CONCLUSIONS: 0.55% cysteamine hydrochloride formulation in HA and packaged in single-dose containers preserved at -20 °C is stable for 120 days protected from light, presenting high potential for its translation into clinical practice when commercial presentations are not available.

8.
Eye Contact Lens ; 49(11): 464-470, 2023 Nov 01.
Article in English | MEDLINE | ID: mdl-37713633

ABSTRACT

OBJECTIVES: To compare the values of central corneal thickness, anterior chamber depth (ACD), lens thickness (LT), vitreous length (VL), axial length (AL), and corneal-compensated intraocular pressure performed with and without contact lenses (CL). METHODS: Forty volunteer participants (16 men and 24 women, 24.2±2.9 years) were recruited. In a single visit, participants underwent autorefraction, keratometry, biometry, topography, pachymetry, and tonometry with the naked eye (without CL). Then, biometry, pachymetry, and tonometry were repeated twice wearing two CL (somofilcon A and nesofilcon A) fitted in a random order. RESULTS: Many of the ocular biometric values were affected by the use of CL during measurements (paired t test; all P ≤0.003), except for LT and VL (Wilcoxon test; both P ≥0.272). Corneal-compensated intraocular pressure was also affected by contact lens wear during measurements, obtaining lower values when wearing them (Wilcoxon test; all P ≤0.001). CONCLUSIONS: Central corneal thickness, ACD, AL, and corneal-compensated intraocular pressure measurements cannot be performed while wearing CL. However, LT and VL measurements were not affected by any contact lens use. In addition, it was observed that ACD results from both devices are not interchangeable either when measured with the naked eye or using any contact lens.


Subject(s)
Contact Lenses , Eye Diseases , Lenses, Intraocular , Male , Humans , Female , Intraocular Pressure , Anterior Chamber/anatomy & histology , Axial Length, Eye/anatomy & histology , Biometry
9.
Expert Rev Med Devices ; 20(8): 681-690, 2023.
Article in English | MEDLINE | ID: mdl-37402231

ABSTRACT

BACKGROUND: Due to the increasing use of contact lenses (CL) and the interest in ocular and body size relationships, this study aimed to compare measurements from two biometers (contact ultrasonic EchoScan US-800 and non-contact optical Lenstar LS900) with and without CL and to explore the relationship between ocular and body biometric parameters. DESIGN AND METHODS: This cross-sectional study measured ocular biometry using two biometers along with their body height and right foot length in 50 participants. Differences between biometry data from the two devices were compared and correlations between ocular and body biometric values were analyzed. RESULTS: All parameters showed interbiometric differences (p ≤ 0.030), except crystalline lens thickness during CL wear (p = 0.159). Comparing measurements with and without CL, differences were observed in axial length (p < 0.001), vitreous length measured by optical biometer (p = 0.016), and anterior chamber depth by ultrasonic biometer (p < 0.016). Lens thickness remained unaffected (p ≥ 0.190). Body height and foot length were correlated with anterior chamber depth, vitreous length, and axial length (p ≤ 0.019, r ≥ 0.330). Most biometric parameters were correlated among them using both devices (p ≤ 0.037, r ≥ 0.296). CONCLUSIONS: These biometers are not interchangeable and CL affects measurements. Body height and foot length correlate with ocular dimensions, and most ocular biometric values correlate positively.


Subject(s)
Contact Lenses , Lens, Crystalline , Humans , Anterior Chamber/anatomy & histology , Lens, Crystalline/anatomy & histology , Cross-Sectional Studies , Axial Length, Eye/anatomy & histology , Biometry , Tomography, Optical Coherence/methods , Reproducibility of Results
11.
Article in English | LILACS-Express | LILACS | ID: biblio-1535293

ABSTRACT

Therapeutic options for incisors affected by Molar Incisor Hypomineralization range from very conservative procedures to those considered to be more invasive. Clinicians must select the appropriate approach, considering the outcomes of the procedures. This case series presents clinical outcomes of five female patients with aesthetic complaints associated with the Molar Incisor Hipomineralization. Macroabrasion, microabrasion and dental vital bleaching were used as combination techniques in three cases. Resin infiltration was indicated for a specific case, considering the oncoming orthodontic treatment. Composite restoration was performed in one patient with posteruptive enamel breakdown. Clinicians must select the appropriate approach according to an individualized evaluation of each case, considering factors such as the patient's expectations, dental age, psychosocial period, the severity of the condition, presence of sensitivity and the presumed aesthetic result of the selected treatment. The advantages and disadvantages of the techniques are presented.


Las opciones terapéuticas para los incisivos afectados por hipomineralización incisivo molar van desde procedimientos muy conservadores hasta los considerados más invasivos. Los clínicos deben seleccionar el enfoque adecuado, teniendo en cuenta los resultados de los procedimientos. Esta serie de casos presenta los resultados clínicos de cinco pacientes femeninas con quejas estéticas asociadas a la Hipomineralización Incisivo Molar. En tres casos se utilizaron la macroabrasión, la microabrasión y el blanqueamiento dental vital como técnicas combinadas. La infiltración de resina fue indicada para un caso específico, considerando el tratamiento de ortodoncia próximo. Se realizó una restauración con composite en un paciente con rotura posteruptiva del esmalte. Los clínicos deben seleccionar el abordaje adecuado de acuerdo con una evaluación individualizada de cada caso, considerando factores como las expectativas del paciente, la edad dental, el período psicosocial, la gravedad de la afección, la presencia de sensibilidad y el resultado estético presumible del tratamiento seleccionado. Se presentan las ventajas e inconvenientes de las técnicas.

12.
Int Ophthalmol ; 43(7): 2349-2362, 2023 Jul.
Article in English | MEDLINE | ID: mdl-36692700

ABSTRACT

PURPOSE: To determine if the Meibomian Gland (MG) secretion quality is associated with symptoms of ocular discomfort, hours of Video Display Terminals (VDT) use, eyelid margin abnormalities, conjunctival hyperemia, and Meibomian Gland Loss Area (MGLA) in a sample of university students. METHODS: An online survey that included an Ocular Surface Disease Index (OSDI) questionnaire and an extra question about hours of VDT use recruited an initial sample of 183 participants. Only 120 participants that fulfilled the inclusion criteria were scheduled for a battery of ocular surface and MG specific exam. The tests include: 1) meibometry, 2) slit lamp exploration of eyelid margin abnormalities (irregularity, hyperemia and MG orifices plugging), MG secretion quality and conjunctival hyperemia, and 3) Meibography. RESULTS: Significant positive correlations between the MG secretion quality and eyelid margin hyperemia, MG orifices plugging, MGLA, nasal conjunctival hyperemia, and temporal conjunctival hyperemia (Spearman Rho; all r>0.186, p<0.042) were found. Multivariate regression found association between OSDI with hours of VDT use (B=0.316, p=0.007), and eyelid hyperemia (B=0.434, p≤ 0.001). A statistical association between MG secretion quality and eyelid margin hyperemia, MG orifices plugging, MGLA and conjunctival hyperemia (Fisher's exact; all p<0.039) were found. Multivariate regression found association between MG secretion quality with MG orifices plugging (B=0.295, p=0.004) and meibometry (B=-0.001, p=0.029). CONCLUSION: Participants with higher values in MG secretion quality have higher values in eyelid margin hyperemia, MG plugging, MGLA, and conjunctival hyperemia. No direct relationship between MG secretion quality and hours of VDT use or OSDI were found.


Subject(s)
COVID-19 , Dry Eye Syndromes , Eyelid Diseases , Hyperemia , Humans , Meibomian Glands , Hyperemia/diagnosis , Universities , Tears , Eyelid Diseases/diagnosis , Students
13.
Cont Lens Anterior Eye ; 46(3): 101800, 2023 06.
Article in English | MEDLINE | ID: mdl-36572605

ABSTRACT

PURPOSE: The present study aimed to determine the relationship of non-modifiable (rheumatoid arthritis, thyroid diseases, and arterial hypertension) and modifiable risk factors (diuretics, antidepressants, or anxiolytics tranquilizers) with the different Dry Eye Disease (DED) diagnostics in a sample adjusted by antihistamines intake. METHODS: A total of 400 participants were included in a cross-sectional study. Before a dry eye examination, participants completed an online self-administered OSDI questionnaire with six additional questions about possible DED risk factors. The Tear Film and Ocular Surface Society Dry Eye Workshop II (TFOS DEWS-II) diagnostic criteria of DED was used. Based on signs and/or symptoms, participants were divided into 4 groups: No DED, Pre-clinical DED, Predisposition to DED and DED. Since the symptom scores would have been altered by the use of antihistamines, the analysis of each outcome was adjusted for this factor, where those participants were assumed to be symptomatic. RESULTS: Multivariable logistic regression found thyroid disease as a possible risk factor for DED (OR 4.53, 95 % CI 1.04-19.73; Fisher's exact, p = 0.044; Cramers V = 0.140, p = 0.024). No association was found between the studied parameters and Pre-clinical DED (Fisher's exact, all p ≥ 0.398; Cramers V, all p ≥ 0.242) or Predisposition to DED (Fisher's exact, all p ≥ 0.065; Cramers V, all p ≥ 0.031). CONCLUSION: Participants with thyroid disease were more likely to develop DED, therefore, thyroid disease could be a risk factor for DED.


Subject(s)
Dry Eye Syndromes , Humans , Cross-Sectional Studies , Dry Eye Syndromes/diagnosis , Dry Eye Syndromes/epidemiology , Risk Factors , Surveys and Questionnaires , Tears
14.
Ocul Immunol Inflamm ; 31(5): 970-977, 2023 Jul.
Article in English | MEDLINE | ID: mdl-35587256

ABSTRACT

OBJECTIVE: Distinguish between EDE severity levels by analysing the MGLA, conjunctival hyperemia and corneal staining. METHODS: One hundred participants were recruited based on OSDI, TO, TFBUT, TMH, and LLP to be categorised as healthy (Group 1) or EDE (Group 2). Group 2 was divided into Group 2A (mild symptoms), 2B (moderate), and 2C (severe). MGLA, conjunctival hyperemia, and corneal staining were measured. RESULTS:  Positive correlation between MGLA, conjunctival hyperemia, and corneal staining were found (all r ≥ 0.221, p ≤ 0.027). Significant differences were found: MGLA between Group 1 vs. 2C and 2C vs. 2A or 2B; conjunctival hyperemia between Group 1 vs. 2A, 2B or 2C; corneal staining between Group 1 vs. 2B or 2C and 2A vs. 2B or 2C (all p ≤ 0.049). CONCLUSION: Severe EDE participants have higher MGLA, conjunctival hyperemia, and corneal staining values than healthy, mild, or moderate EDE participants.


Subject(s)
Conjunctivitis , Dry Eye Syndromes , Hyperemia , Humans , Hyperemia/diagnosis , Tears , Dry Eye Syndromes/diagnosis
15.
Clin Exp Optom ; 106(4): 351-361, 2023 05.
Article in English | MEDLINE | ID: mdl-35410571

ABSTRACT

The measurement of tear film osmolarity has been suggested as a gold standard in the diagnosis of dry eye. Many tear film physiological variables oscillate during the day. This review summarises current clinical knowledge regarding diurnal osmolarity variation in the tear film. A critical analysis is presented in respect of of sample size and characteristics, differences in the diurnal osmolarity variation on healthy versus altered tear film conditions or environment, and time of day and number of measurements undertaken. A comparison of 21 studies was made for studies in which one of the main objectives was to analyse the variance of tear film osmolarity at different time-points in a day on human cohorts. Tear film osmolarity appeard to be somewhat influenced by the time of day in healthy subjects and patients with ocular surface disease, or altered by environmental conditions. Both healthy and non-physiological tear film cohorts showed variations in results depending on the study: no variations during the day or statistically different values at some point in the day. These differences could be in the middle of the day or between the beginning and the end of the day, with higher values in the morning than in the afternoon, or even the opposite situation. The possibility of diurnal variations in tear film osmolarity should be considered by the clinician since the time of day when the tear film measurements are made can be critical in making the right diagnosis. Future studies in the diurnal variation field may have to use a well-established range of measurement time-points and a larger group of healthy subjects and and subjects who have a tear film altered by pathological or environmental conditions.


Subject(s)
Dry Eye Syndromes , Humans , Osmolar Concentration , Dry Eye Syndromes/diagnosis , Tears/physiology
16.
Life (Basel) ; 12(12)2022 Dec 02.
Article in English | MEDLINE | ID: mdl-36556372

ABSTRACT

A decrease of the Tear Meniscus Height (TMH) has been proposed as a useful indicator for Aqueous Deficient Dry Eye (ADDE) categorization. The present study aimed to calculate a TMH cut-off criterion for the categorization or severity assessment of ADDE with the Tearscope. 200 participants with a previous Dry Eye Disease (DED) diagnosis according to TFOS DEWS-II criteria were recruited. TMH by slit-lamp illumination and Lipid Layer Pattern (LLP) with Tearscope were assessed to categorise the participants into the ADDE or the Evaporative Dry Eye (EDE) group. The ADDE group was also subdivided into Mild-moderate ADDE and Moderate-severe ADDE based on TMH with slit-lamp. Additionally, the TMH was measured by Tearscope (TMH-Tc). Receiver Operating Characteristics showed that the TMH-Tc have a diagnostic capability to differentiate between ADDE and EDE participants, and between Mild-moderate or Moderate-severe ADDE, with a cut-off value of 0.159 mm (AUC = 0.843 ± 0.035, p < 0.001; sensitivity: 86.4%; specificity: 75.4%) and 0.105 mm (AUC = 0.953 ± 0.025, p < 0.001; sensitivity: 98.1%; specificity: 80.0%), respectively. The present study proposed a cut-off criterion to differentiate between ADDE and EDE participants, or between ADDE severities through TMH assessed by Tearscope.

17.
Optom Vis Sci ; 99(2): 159-166, 2022 02 01.
Article in English | MEDLINE | ID: mdl-34897233

ABSTRACT

SIGNIFICANCE: Tear film instability has been recognized as one key mechanism on dry eye disease. There is a need for new instruments, methods, or protocols to improve the repeatability and reproducibility of the tear film stability to facilitate its clinical evaluation use as a rapid and reliable primary diagnostic test. PURPOSE: The present pilot study aimed to validate a method to automatically measure the tear film breakup time (BUT). METHODS: A total of 264 videos of BUT were randomly selected among the clinical history of subjects attending the optometry clinic. Videos were stored in a backup server through a secure file transfer protocol and analyzed by three different examiners: two masked observers (subjective evaluation) and a third investigator using the automatic software application (objective evaluation). Subjective evaluation was conducted only once on an online software designed for this protocol where videos were presented in random masked order. Automatic evaluation based on color and texture analysis was performed by (1) automatic localization of sequences of interest in the video, (2) extraction of the region of interest within each frame, and (3) automatic BUT measurement from evolution curves in the region of interest as time elapsed from the beginning of the sequence of interest until the curve exceeds a threshold. RESULTS: Substantial correlation was observed among the examiners (intraclass correlation coefficient, 0.752). There was a statistical difference between observer 1 and 2 evaluations (t test, P < .001), whereas data provided by the software showed no significant differences from those of the observers (t test, P ≥ .26). Similar results to the whole data set analysis were obtained when the sample was reassessed only considering mean BUT values ≤15 seconds. CONCLUSIONS: The present pilot study showed acceptable clinical results for the software application designed to objectively measure the BUT.


Subject(s)
Dry Eye Syndromes , Tears , Dry Eye Syndromes/diagnosis , Humans , Pilot Projects , Reproducibility of Results , Software
18.
Clin Exp Optom ; 104(6): 691-697, 2021 08.
Article in English | MEDLINE | ID: mdl-33689665

ABSTRACT

CLINICAL RELEVANCE: Variation with time in the tear film parameters should be considered by the clinician since the time when measurements are made can influence proper diagnosis. BACKGROUND: A hallmark of dry eye is an unstable tear film associated with variability in objective daily measures. The purpose of the present study was to evaluate the inter-week repeatability of meibometry, break-up time (BUT) and maximum blink interval (MBI) in healthy subjects. METHODS: Forty healthy subjects were recruited for the study. Meibometry, BUT and MBI were performed twice in two sessions, one-week apart. Meibum from the lower eyelid was collected and quantified with the Meibometer MB550. Five meibomian curves were generated by tape and each peak value was averaged as a mean value per session. BUT and MBI were determined three times after fluorescein instillation and recorded by a DV-3 camera attached to the slit lamp. BUT and MBI videos were analysed by a second masked observer. Both BUT and MBI values were calculated by averaging the two most similar measurements of the three evaluated. RESULTS: No statistical difference between inter-week sessions was obtained for the meibometry (p > 0.340; Wilcoxon test), BUT (p > 0.326; Wilcoxon test) and MBI values (p ≥ 0.248; Wilcoxon test). Inter-week differences were low for BUT and MBI when time intervals were no longer than 15 seconds (both p ≥ 0.586; Wilcoxon test). A correlation between BUT and MBI was found (r ≥ 0.668, p < 0.001; Spearman Rho), while a no statistical correlation was obtained between meibometry results and BUT or MBI (all p ≥ 0.194; Spearman Rho). CONCLUSION: Meibum secretion and the tear film stability present good intersession repeatability, and are stable along with sessions in healthy patients.


Subject(s)
Dry Eye Syndromes , Tears , Blinking , Dry Eye Syndromes/diagnosis , Fluorescein , Healthy Volunteers , Humans
19.
Cont Lens Anterior Eye ; 44(4): 101379, 2021 Aug.
Article in English | MEDLINE | ID: mdl-33187860

ABSTRACT

PURPOSE: The physical properties of contact lens care solutions and Eye Drops (ED) may affect initial comfort and dry eye symptomatology in contact lens wearers, although these properties are not always provided by manufacturers. The present study aimed to measure and compare the osmolality and pH of commercially available contact lens care solutions and ED. METHODS: Forty-four solutions were tested (17 lens care solutions and 27 ED) and classified by the presence and/or combination of the viscosity/lubrication-enhancing ingredients. Solution osmolality was obtained with the Fiske 110 osmometer and pH was measured with a micro-pH 2000. Each measurement was taken ten times, following the manufacturer's instructions, while controlling for room temperature and humidity. Differences between the values of the physical properties of the solutions were analysed by type and viscosity/lubrication-enhancing agent subclassification. RESULTS: Osmolality ranged from 192.6 ± 2.17 to 364.6 ± 2.88 mOsm/Kg, while pH ranged from 6.35 [6.35-6.26] to 7.99 [7.99-8.00]. A significant difference in the osmolality and pH values of contact lens care solutions and ED was found when classified by type or viscosity/lubrication-enhancing agent (ANOVA and Kruskal-Wallis respectively, both p < 0.001). CONCLUSIONS: The physical properties of some contact lens care solutions and ED are not readily available. The osmolality and pH values of various commercially available lens care solutions and ED vary significantly both by type and viscosity/lubrication-enhancing ingredients.


Subject(s)
Contact Lens Solutions , Contact Lenses , Humans , Hydrogen-Ion Concentration , Ophthalmic Solutions , Osmolar Concentration
20.
Rev. odontopediatr. latinoam ; 11(2): 320196, 2021.
Article in Spanish | LILACS, COLNAL | ID: biblio-1417079

ABSTRACT

En torno al blanqueamiento dental existen muchas afirmaciones con poco soporte científico, tales como: los blanqueamientos son ácidos, dañan el esmalte, se utilizan férulas, hay restricción en dieta y en la gestación, con límite mínimo de edad para su uso, entre otros. Para la odontología es de suma importancia que toda afirmación se realice responsablemente con una evidencia científica para entregar lo mejor de cada tratamiento a los pacientes. Objetivo: Conocer las posibles indicaciones del blanqueamiento dental en niños y adolescentes, modalidades, los efectos sobre los tejidos blandos y duros, así como sus efectos secundarios, la hipersensibilidad dentinaria, su tratamiento farmacológico y su impacto psicosocial. Material y métodos: se realizó una búsqueda electrónica de los siguientes buscadores: PubMed, LILACS, SCIELO, Cochrane Library y SCOPUS, limitando la búsqueda entre los años 1998 y 2020 utilizando los términos relacionados a la investigación. Se incluyeron 71 artículos que cumplieron con los criterios de inclusión. Resultados: la mayoría de los autores recomiendan el uso de sistemas de blanqueamiento dental de acuerdo con parámetros establecidos.


Regarding teeth bleaching, there are many statements with little scientific support, such as: whitening is acidic, damages the enamel, guards are used, there is a restriction in diet and pregnancy, with a minimum age limit for its use, between others. For dentistry it is of utmost importance that all statements are made in a responsible manner with scientific evidence to provide the best of each treatment to patients. Objective: to know the possible indications for teeth bleaching in children and adolescents, the modalities, the effects on soft and hard tissues, as well as its side effects, dental hypersensitivity, its pharmacological treatment and its psychosocial impact. Material and methods: An electronic search of the following databases was performed: PubMed, LILACS, SCIELO, Cochrane Library and SCOPUS, limiting the search between 1998 and 2020 using the terms related to the research. Seventy-one articles that met the inclusion criteria were included. Results: Most authors recommend the use of teeth whitening systems according to established parameters


No que diz respeito ao clareamento dos dentes, existem muitas afirmações com pouco apoio científico todas as declarações sejam feitas de maneira responsável com evidências científicas para oferecer o melhor de cada tratamento aos pacientes. Objetivo: Conhecer as possíveis indicações para clareamento dental em crianças e adolescentes, modalidades, efeitos sobre os tecidos moles e duros, bem como seus efeitos colaterais, hipersensibilidade dentária, tratamento farmacológico e impacto psicossocial. Material e métodos: Foi realizada uma busca eletrônica nos seguintes mecanismos de busca: PubMed, LILACS, SCIELO, Cochrane Library e SCOPUS, limitando a busca entre 1998 e 2020, utilizando os termos relacionados à pesquisa. Setenta e um artigos que atenderam aos critérios de inclusão foram incluídos. Resultados: A maioria dos autores recomenda o uso de sistemas de clareamento dental de acordo com os parâmetros estabelecidos


Subject(s)
Humans , Child , Adolescent , Tooth Bleaching , Hypersensitivity , Reference Standards , Psychosocial Impact , Dental Enamel